Compliance verification activity type: Field Inspection
Team:
Regulated company: Enbridge Pipelines (NW) Inc.
Operating company: Enbridge Pipelines (NW) Inc.
Province(s) / Territory(s):
Discipline(s):
Rationale and scope:
Line 21 replacement project, HDD construction safety. Verify compliance with the OPR, CLC, company-specific construction safety program requirements and project specific conditions. Focus areas include HDD safe operations, public and worker safety, and integration of the contractor safety management system.
Compliance tool(s) used:
Facilities:
Facility Types
Life-cycle Phases
Regulatory requirements that apply to this activity:
Regulatory instrument number(s):
Observation 1 - General Observation of North and South Side of Line 21 Project
Date & time of visit: 2018-07-17 14:05
Discipline: Safety Management
Categories:
Facility:
Observations:
General Observations:
Compliance tool used: No compliance tool used
Observation 2 - CNC#1 Inadequate grounding and bonding
Date & time of visit: 2018-07-17 16:00
Inadequate Bonding & Grounding was a common occurrence across both North and South locations,camp and drill sites (CNC-1).
Compliance tool used: Corrected Non-compliance (CNC)
Regulatory requirement:
Relevant section(s):
Company action required:
Company shall resolve the Bonding and Grounding issue for Camp and Drill sites, as per Enbridge LP/MP Safety Manual version 2.4 section 4.13 Bonding and Grounding.
Due date: 2018-07-19
Date closed: 2018-07-18 Note: the date closed is the date that the inspector completed their review of the company corrective actions for adequacy and determined that no further actions are required.
Reason closed: Requirement met
Compliance achieved: Yes
Observation 3 - CNC#2: Propane tank missing controlled product Placard label
Date & time of visit: 2018-07-17 17:20
WHMIS Hazardous Gas Placard label missing on one of the propane tanks located in south camp site.
Company shall place Controlled Products Placard on propane cylinder that is mounted on camp trailer as per Enbridge LP/MP Safety Manual, version 2.4, section 14.5, GHS/WHIMIS/HAZCOM.
Due date: 2018-07-17
Date closed: 2018-07-17 Note: the date closed is the date that the inspector completed their review of the company corrective actions for adequacy and determined that no further actions are required.
Observation 4 - CNC#3: Expired dates on First Aid kit supplies
Date & time of visit: 2018-07-17 17:00
First aid kit contents with expired dates.
Observation 5 - CNC#4: Wheel Chocks not placed on parked/stationary flat deck trailers
Flat deck trailers missing wheel chocks.
Company shall chock all flat deck trailers that are stored/parked on site per Enbridge, Safety Manual, version 2.4.
There are no observations with outstanding follow-up
Observation 6 - CNC#7: Mud product, Star Plex Safety Data Sheet (SDS) missing from SDS binder
Date & time of visit: 2018-07-18 13:30
Star- Plex mud additive (controlled product) SDS documentation not in SDS binder.
Company shall print and place Mud Product, Star Plex safety data sheet (SDS) in the SDS binders where product resides per Enbridge LP/MP Safety Manual, version 2.4, section 14.5 GHS/WHMIS/HAZCOM.
Due date: 2018-07-18
Observation 7 - CNC#8: Rigging slings rating tags not legible and not fit for use
Rigging slings rating tags not legible, appear worn, and not fit for use.
Company must take both worn slings and slings with either no tags or unreadable tags out of service. The slings need to be destroyed and I.D. tags removed per Enbridge LP/MP Safety Manual, version 2.4, section 19.5, Inspection and Maintenance.
Date closed: 2018-07-19 Note: the date closed is the date that the inspector completed their review of the company corrective actions for adequacy and determined that no further actions are required.
Observation 8 - CNC#9: Workers not wearing hearing protection in designated area as required
Date & time of visit: 2018-07-18 14:30
Two workers in a crew were not wearing hearing protection in a work area where administrative controls clearly identified hearing protection was a requirement.
Company must ensure workers wear PPE as required and identified by Administrative Control signage placed in specific work areas that require hearing protection per Enbridge LP/MP Safety Manual version 2.4, section 7.6 Hearing Conservation.
Observation 9 - CNC#11: Combustible and flammable product storage
Date & time of visit: 2018-07-18 16:30
Storage of Oxygen cylinder and Acetylene cylinder not properly separated .
Company shall ensure that Oxygen cylinders are not stored in same area as Acetylene cylinders, and that oxygen/acetylene cylinders are 6.0m or 20 feet apart from each other, stored in an outside environment per Enbridge LP/MP Safety Manual, version 2.4, section 20.6 Compressed Gas Cylinder Storage (Compressed Gas Cylinder Storage).
Observation 10 - CNC#6: Eyewash station bottle not completely filled
Date & time of visit: 2018-07-18 11:30
Eyewash station bottle - not full. Questionable as to whether it had been previously used.
Company shall inspect and monitor eyewash stations to ensure sufficient amount of eyewash bottles in place, expiry dates have not elapsed, and that bottles are full per Enbridge LP/MP Safety Manual, version 2.4, section 11.1 First Aid Equipment- Eyewash Stations
Observation 11 - CNC#10: - Hydrovac was not bonded to an earth ground
Date & time of visit: 2018-07-18 14:45
Enbridge Safety grounding standard pertaining to Hydro-vac trucks, was not being followed, as the Hydro-vac truck was not bonded & grounded to earth.
Company shall ensure that Hydro-vac truck is is properly grounded as per Enbridge LP/MP Safety Manual, version 2.4 section 4.13 Bonding & Grounding.
Identified non-compliances to company plans or procedures are non-compliances either to:
- the condition of an authorization document that requires the implementation of that plan or procedure; or
- the relevant section of the regulations that requires implementation of that plan or procedure including those sections that require implementation of plans or procedures as a part of a Program