Compliance Verification Activity Report: CV1718-114 - TransCanada PipeLines Limited

Overview

Compliance verification activity type: Field Inspection

Activity #: CV1718-114
Start date: 2017-10-03
End date: 2017-10-04

Team:

Regulated company: TransCanada PipeLines Limited

Operating company: TransCanada PipeLines Limited

Province(s) / Territory(s):

Discipline(s):

Related events:

Rationale and scope:

This activity is a field inspection of right-of-way between North Bay, ON - Oshawa, ON. Inspection will verify compliance to OPRs and DPRs, inclusive of site visits to reported unauthorized activity locations, third party construction locations, and road/rail crossings within the Rideau and Maple & Niagara areas.

Compliance tool(s) used:

Facility details

Facilities:

Regulatory requirements

Regulatory requirements that apply to this activity:

Observations (no outstanding follow-up required)

Observation 1 - Tuesday 3 October 2017 - RoW Inspection between North Bay and Huntsville, ON

Date & time of visit: 2017-10-03 08:00

Discipline: Damage Prevention

Categories:

Facility:

Observations:

NEB Inspection Officers and TCPL staff conducted a right-of-way(RoW) inspection of signage, vegetation management to ensure clear visibility and access of the RoW, historical unauthorized activity locations, and third-party activity at various locations along the TCPL RoW between North Bay and Huntsville, ON. The RoW at the following locations was observed to be maintained in accordance with CSA Z662 10.6.2. Site locations were as follows:

46.3761 / -79.4661 (Highway 11 at Barnett Road, North Bay, ON - Site of UX2016-047):

46.3737 / -79.4570 (Marsh Drive, North Bay):46.3234 / -79.4134 (Sage Road, North Bay - Site of 3rd party authorized activity to construct a bus stop):46.1995 / -79.3538 (Nighway 11 / Lake Nosbonsing Road, North Bay - Site of UX2016-063):46.0482 / -79.3516 (English Line near Maple Hill Road, south of Powassan, ON):45.9990 / -79.3698 (Hemlock Road / McCarthy Street, near Trout Creek, ON). 45.7184 / -79.4373 (Sunridge Compressor Station 119, Sunridge, ON):45.3389 / -79.2396 (Ravensglen Crescent, Huntsville, ON): 45.3411 / -79.2373 (Williams Street, Hunstville, ON): 45.3378 / -79.2408 (Huntsville Meter Station, Ravenscliffe Road, Huntsville, ON):

Compliance tool used: No compliance tool used

Observation 2 - CNC #1 of 2 - RoW signage did not indicate type of pipeline system

Date & time of visit: 2017-10-03 10:10

Discipline: Damage Prevention

Categories:

Facility:

Observations:

NEB Inspectors observed signage for three TCPL lines at this road crossing location, however the signage did not display information regarding the type of pipeline system (High-Pressure Natural Gas Pipeline). This was in non-compliance with CSA Z662-15 10.5.3.3(b).

Compliance tool used: Corrected Non-compliance (CNC)

Regulatory requirement:

Relevant section(s):

Company action required:

TCPL verbally agreed to replace the RoW signage at this location such that it indicates the type of pipeline system (High-Pressure Natural Gas Pipeline) per the requirements of CSA Z664-15 10.5.3.3(b).

 

Due date: 2017-10-05

Date closed: 2017-10-04
Note: the date closed is the date that the inspector completed their review of the company corrective actions for adequacy and determined that no further actions are required.

Reason closed: Requirement met

Compliance achieved: Yes

Observation 3 - Wednesday 4 October 2017 - RoW Inspection between Barrie, ON and Oshawa, ON

Date & time of visit: 2017-10-04 07:00

Discipline: Damage Prevention

Categories:

Facility:

Observations:

NEB Inspection Officers and TCPL staff conducted a RoW inspection of signage, vegetation management to ensure clear visibility and access of the RoW, historical unauthorized activity locations, and third-party authorized activity at various locations along the TCPL RoW between Barrie, ON and Oshawa, ON. The RoW at the following locations was observed to be maintained in accordance with CSA Z662 10.6.2. Site locations were as follows:

44.3396 / -79.7398 (County Road 27, Barrie, ON - Site of UX2016-116):

44.2755 / -79.7222 (Innisfil Beach Rd, Thornon, ON):44.2651 / -79.71426 (7th LIne, Thornton / Essa, ON): 43.8369 / -79.6476 (Creedmore Crt, Vaughan, ON - Site of UX2016-152)43.9305 / -79.6591 (East's Corners Blvd, Vaughan, ON):43.8349 / -79.6502 (near East's Corners Blvd at Mactier Dr, Vaughan, ON - Rail Crossing):43.8948 / -79.5472 (Jane Street, Vaughan, ON):43.9075 / -79.4230 (Bayview Avenue / Richmond Hill Meter Station, Richmond Hill, ON - Site of UX2016-172):43.9238 / -79.3516 (Warden Avenue, Markham, ON):43.9402 / -79.2495 (9th Line, Markham Sales Meter Station, Markham, ON - Site of UX2016-134):43.9645 / -78.8605 (Harmony Road N, Oshawa Meter Station):43.9601 / -78.7778 (Solina Road - Site of UX2017-145):43.9712 / -78.7715 (Rundle Road - Active Construction Site for 407 Extension Project):

Compliance tool used: No compliance tool used

Observation 4 - CNC #2 of 2 - RoW signage did not indicate the word "Warning", "Caution", or "Danger" and contained an invalid emergency number

Date & time of visit: 2017-10-04 10:25

Discipline: Damage Prevention

Categories:

Facility:

Observations:

NEB Inspectors observed signage for two TCPL lines at this rail crossing location, however the signage did not display the word "Warning", "Caution", or "Danger" as required to be compliant with CSA Z662-15 10.5.3.3(a). In addition, the signage appeared weathered and faded, and displayed the emergency phone number 1-800-827-5094. All signage that was inspected prior to this location displayed the emergency phone number 1-888-982-7222.

NEB Inspectors dialed the emergency telephone number displayed on the signage at this location (1-800-827-5094) and were connected to a voicemail message advising to call a different number which is non-compliance to 10.5.3.3(c).

Compliance tool used: Corrected Non-compliance (CNC)

Regulatory requirement:

Relevant section(s):

Company action required:

TCPL verbally agreed to replace the RoW signage at this location with new two-sided signage such that the information on the signage displays the word "Warning" and displays a current emergency telephone number (1-888-982-7222) as required to be compliant with CSA Z662-15 10.5.3.3 (a) &(c). 

 

Due date: 2017-10-05

Date closed: 2017-10-05
Note: the date closed is the date that the inspector completed their review of the company corrective actions for adequacy and determined that no further actions are required.

Reason closed: Requirement met

Compliance achieved: Yes

Observations (company follow-up required)

Identified non-compliances to company plans or procedures are non-compliances either to:

- the condition of an authorization document that requires the implementation of that plan or procedure; or

- the relevant section of the regulations that requires implementation of that plan or procedure including those sections that require implementation of plans or procedures as a part of a Program